MIDTOWN GENERATOR

MIDTOWN GENERATOR

The project scope of work included design for two 1,000 KW stand-by diesel generators to replace the existing three turbine generators.

ST. PAUL'S EPISCOPAL CHURCH

ST. PAUL'S EPISCOPAL CHURCH

HVAC Modernization and interior renovation at this historic church in Alexandria, VA. Project included approx. 11,000 sq. ft. of interior renovation within an approx. 22,000 sq. ft. of space receiving HVAC upgrades. The project was designed in collaboration with Kerns Group Architects.

DesignTech’s scope of services began with a preliminary options report where four different HVAC solutions were compared and contrasted. This report included schematic mechanical plans, visual and technical HVAC equipment data, and a budgetary construction cost estimate developed by Harris Company.

Following the preliminary options report, two HVAC solutions were compared in a Life Cycle Cost Analysis (LCCA). Option 1 was a 4-pipe chiller/boiler system and Option 2 was a Variable Refrigerant Flow system. The LCCA report provided detailed energy and economic analysis to inform the church’s decision to ultimately pursue Variable Refrigerant Flow.

DesignTech and Kerns Group Architects provided construction documents for bid and permit and construction administration to Harry Braswell Company, who served as the construction manager. The installation of the new HVAC equipment required approval from and detailed communication with the Alexandria Board of Architectural Review (BAR).

D.C. CRITICAL FACILITY COOLING TOWER REPLACEMENT

D.C. CRITICAL FACILITY COOLING TOWER REPLACEMENT

Replacement of four existing roof-mounted, 650-ton cooling towers with new. Project was completed in coordination with Holbert Apple & Associates structural engineers. This 300,000+ sq. ft. critical facility required a phased replacement of each cooling tower and detailed construction administration services to ensure a successful installation.

VERIZON RIGGS RD. CHILLER PLANT UPGRADE

VERIZON RIGGS RD. CHILLER PLANT UPGRADE

Replacement of split air-cooled chillers, chilled water pumps, and basement air handling unit.

HISTORIC CHRIST CHURCH

HISTORIC CHRIST CHURCH

Full renovation of Heating/Cooling systems including addition of central cooling for the Memorial Parish House at the Historic Christ Church campus in Alexandria, VA.

HOOD COLLEGE TATEM ARTS CENTER

HOOD COLLEGE TATEM ARTS CENTER

A full retrofit of the Tatem Arts Center included 52,000 sq. ft. of renovation, 6,500 sq. ft. of an auditorium infill, and 6,500 sq. ft. of addition.

BALLSTON GARAGE LIGHTING RETROFIT

BALLSTON GARAGE LIGHTING RETROFIT

Replacement of existing 175W HID light fixtures throughout a 1 million square foot parking garage with 99W LED type light fixtures with individual motion sensor controls.

WHITE FLINT PROFESSIONAL BUILDING

WHITE FLINT PROFESSIONAL BUILDING

Core renovation for the five story office building in Rockville, MD. Renovation included MEP upgrades as well as a cosmetic renovation of ceilings, finishes, and fixtures.

VERIZON HYATTSVILLE CHILLER PLANT UPGRADE

VERIZON HYATTSVILLE CHILLER PLANT UPGRADE

Phased demolition and upgrade of chilled water plant including air cooled condensers, chillers, and pumps.

DC PUBLIC SCHOOL BOILER REPLACEMENTS

DC PUBLIC SCHOOL BOILER REPLACEMENTS

DesignTech was enlisted onto a design-build team whose project scope included complete renovation of the boiler plants at seven DC public schools.

FEDERAL EMERGENCY MANAGEMENT AGENCY

FEDERAL EMERGENCY MANAGEMENT AGENCY

Multi-million dollar HVAC Upgrade for seven dormitory and office buildings at the Emmitsburg, MD Campus.

WNYW HEATING UPGRADES

WNYW HEATING UPGRADES

Phase 1 in an effort to transfer the building heating system from low pressure steam to heating hot water as well as the air systems from constant volume reheat to variable air volume (VAV).

ERICKSON RLTV

ERICKSON RLTV

The RLTV, Retirement Living Television broadcasting facility and corporate data center is a 100,000 sq. ft. five level office building located at UMBC.

SPRINT 4G LAB HERNDON, VA

SPRINT 4G LAB HERNDON, VA

The project included 17,000 sq. ft. renovation comprised of electronics lab, DC power plant, RF testing chambers and UPS room.

1 2 3 4 5 6 7 8 9 10 11 12 13 14
Previous Next
MIDTOWN GENERATOR
ST. PAUL'S EPISCOPAL CHURCH
D.C. CRITICAL FACILITY COOLING TOWER REPLACEMENT
VERIZON RIGGS RD. CHILLER PLANT UPGRADE
HISTORIC CHRIST CHURCH
HOOD COLLEGE TATEM ARTS CENTER
BALLSTON GARAGE LIGHTING RETROFIT
WHITE FLINT PROFESSIONAL BUILDING
VERIZON HYATTSVILLE CHILLER PLANT UPGRADE
DC PUBLIC SCHOOL BOILER REPLACEMENTS
FEDERAL EMERGENCY MANAGEMENT AGENCY
WNYW HEATING UPGRADES
ERICKSON RLTV
SPRINT 4G LAB HERNDON, VA
facebook twitter linkedin-unauth instagram

Home / Contact / Blog

Mechanical/Electrical/Plumbing Engineering Services

Innovative Designs and Solutions

Mechanical/Plumbing/Electrical Consulting Engineering

DesignTech Inc | 10410 Kensington Pkwy, Kensington, MD, 20895, United States

facebook twitter linkedin-unauth instagram